Gel  /  Gel  /  Datasheet

ATB Gel 12-38

Gel DC Series · Deep Cycle Gel VRLA
ATB-GEL-DCG12-38

Deep-cycle gel.
Tough on heat and cycling.

A 12 V 40 Ah gel VRLA battery for solar, deep-cycle, mobility and marine use. The gelled electrolyte gives strong deep-cycle life and tolerance to heat and irregular charging. Sealed, maintenance-free and non-spillable, with M6 bolt terminals.

ATB-GEL-DCG12-38
12 V
Nominal voltage
40 Ah
C20 capacity @ 25°C
380 A
Max discharge (5 s)
12.7 kg
Approx. weight

Sealed gel VRLA

Valve-regulated oxygen-recombination design. Maintenance-free and non-spillable: no electrolyte topping and no acid handling.

M6 bolt terminals

Threaded M6 terminals for secure bolted cable connections in UPS and standby systems.

Gelled electrolyte

Fumed-silica gel immobilises the electrolyte for deep-cycle life and heat tolerance.

Standard footprint

197 × 166 × 170 mm case.

SPECIFICATIONS

MECHANICAL

Length197 mm ±2.0
Width166 mm ±1.5
Container height170 mm ±2.0
Overall height170 mm ±2.0
Approx. weight12.7 kg ±3%
Container materialABS, UL94-HB (UL94-V0 optional)
Terminal typeM6 bolt terminal

ELECTRICAL

Nominal voltage12 V
ChemistryGEL VRLA (sealed)
Capacity, 20 hr (C20)40 Ah
Capacity, 10 hr (C10)38 Ah
Capacity, 5 hr (C5)32.7 Ah
Rating basisto 1.80 V/cell @ 25°C
Float voltage @ 25°C13.5 – 13.8 V
Equalizing voltage @ 25°C14.4 – 15.0 V
Max charge current11.4 A
Max discharge current380 A (5 s)
Internal resistance (charged)≈ 13.5 mΩ
Operating temp. (dis / chg)−15°C~50°C / −15°C~40°C
Storage temp.−15°C~40°C
CONTAINER DRAWING — DIMENSIONS IN MM
Container drawing
Technical Specification

ATB-GEL-DCG12-38 — technical data

CONSTANT CURRENT DISCHARGE @ 25°C · UNIT: A
F.V (V/cell) / Time10 min15 min30 min1 h3 h5 h10 h20 h
1.60 V70.059.938.124.010.57.094.012.16
1.67 V67.758.135.923.310.57.043.992.15
1.70 V64.355.835.022.910.36.923.952.13
1.75 V61.553.133.422.110.06.713.912.07
1.80 V56.749.132.019.79.626.543.802.02
1.85 V49.943.327.517.88.776.203.721.92
CONSTANT POWER DISCHARGE @ 25°C · UNIT: W/CELL
F.V (V/cell) / Time10 min15 min30 min1 h3 h5 h10 h20 h
1.60 V12210668.445.120.113.87.854.13
1.67 V12010565.544.120.013.77.804.09
1.70 V11510164.143.419.813.57.764.05
1.75 V11297.961.942.419.413.27.723.97
1.80 V10591.759.738.118.812.87.513.85
1.85 V94.082.052.034.717.212.27.383.68
EFFECT OF TEMPERATURE ON CAPACITY (10 HR)
TemperatureCapacity (10 HR)
40 °C102%
25 °C100%
0 °C85%
−15 °C65%
SELF-DISCHARGE CHARACTERISTICS
Storage timeRemaining capacity
3 months91%
6 months82%
12 months64%
CHARACTERISTIC CURVES
Discharge Characteristics
TERMINAL VOLTAGE (V/CELL) vs DISCHARGE TIME · 25°C / 20°C
Discharge Characteristics
Charging Characteristics
0.1 CA · 2.25 V/CELL @ 25°C
Charging Characteristics
Capacity Retention (Self-Discharge)
CAPACITY RETENTION RATIO vs STORAGE TIME
Capacity Retention (Self-Discharge)
Float Service Life
FLOAT LIFE vs BATTERY TEMPERATURE · 2.25 V/CELL
Float Service Life

STANDARDS & QUALITY

Gel VRLA batteries produced by an ATB-approved manufacturing partner whose VRLA batteries are UL-recognized components under UL 1989, in facilities certified to ISO 9001, ISO 14001 and ISO 45001. Sealed, non-spillable VRLA construction.

Values are subject to variation of ±5% under normal manufacturing processes. Technical specifications are subject to change without prior notice. Curves represent typical performance for the gel VRLA cell platform at the stated reference conditions. This product is engineered, specified and branded by ATB Power. E&OE. © ATB Power.