Start-stop AGM.
For deep-cycle use.
A 12 V 92 Ah AGM VRLA battery in the automotive start-stop case (BCI group 49, LN5/H8), offered for deep-cycle use. Sealed, maintenance-free and non-spillable, with automotive post terminals.

Sealed AGM VRLA
Valve-regulated oxygen-recombination design. Maintenance-free and non-spillable: no electrolyte topping and no acid handling.
Automotive post terminals
Tapered positive and negative posts, dimensions in the drawing below.
Automotive case
BCI group 49, LN5/H8 case with B13 hold-down, 353 × 175 × 190 mm.
Cranking and reserve
850 A cold cranking current at −18 °C and 160 min reserve capacity at 25 A.
MECHANICAL
| Length | 353 mm ±1.5 |
| Width | 175 mm ±1.5 |
| Container height | 190 mm +0/−3 |
| Overall height | 190 mm +0/−3 |
| Approx. weight | 26.8 kg |
| Container material | Black PP |
| Terminal type | Automotive post (see drawing) |
| Hold-down | B13 |
| BCI group | 49 |
| Shape standard | LN5/H8 |
ELECTRICAL
| Nominal voltage | 12 V |
| Capacity, 20 hr (C20) | 92 Ah |
| Capacity, 10 hr (C10) | 81.5 Ah |
| Capacity, 5 hr (C5) | 70.5 Ah |
| Rating basis | to 1.75 V/cell (10.5 V) |
| Reserve capacity | 160 min (25 A to 10.5 V) |
| Cold cranking current | 850 A (−18 °C) |

ATB-AGM-DC12-L5 — technical data
| F.V (V/cell) / Time | 30 min | 45 min | 1 h | 3 h | 5 h | 8 h | 10 h | 20 h |
|---|---|---|---|---|---|---|---|---|
| 1.60 V | 81.3 | 60.5 | 50.6 | 21.8 | 14.7 | 10.3 | 8.43 | 4.74 |
| 1.67 V | 79.0 | 58.9 | 49.3 | 21.4 | 14.4 | 10.2 | 8.30 | 4.68 |
| 1.70 V | 77.7 | 58.2 | 48.8 | 21.2 | 14.3 | 10.1 | 8.24 | 4.65 |
| 1.75 V | 76.1 | 57.1 | 48.0 | 20.9 | 14.1 | 9.99 | 8.15 | 4.60 |
| 1.80 V | 74.2 | 56.0 | 47.2 | 20.6 | 14.0 | 9.87 | 8.04 | 4.56 |
| 1.85 V | 72.4 | 54.9 | 46.3 | 20.3 | 13.7 | 9.74 | 7.96 | 4.51 |
| F.V (V/cell) / Time | 30 min | 45 min | 1 h | 3 h | 5 h | 8 h | 10 h | 20 h |
|---|---|---|---|---|---|---|---|---|
| 1.60 V | 154 | 115 | 96.6 | 42.5 | 28.7 | 20.5 | 16.7 | 9.49 |
| 1.67 V | 150 | 112 | 94.8 | 41.8 | 28.3 | 20.1 | 16.5 | 9.36 |
| 1.70 V | 148 | 111 | 94.0 | 41.4 | 28.0 | 20.0 | 16.4 | 9.30 |
| 1.75 V | 145 | 110 | 92.8 | 40.9 | 27.8 | 19.7 | 16.1 | 9.20 |
| 1.80 V | 143 | 108 | 91.5 | 40.4 | 27.4 | 19.6 | 16.0 | 9.10 |
| 1.85 V | 140 | 107 | 90.0 | 39.9 | 27.1 | 19.4 | 15.9 | 9.02 |
Discharge data for this model are ATB ratings for deep-cycle use.
EFFECT OF TEMPERATURE ON CAPACITY (10 HR)
| Temperature | Capacity (10 HR) |
|---|---|
| 40 °C | 102% |
| 25 °C | 100% |
| 0 °C | 85% |
| −15 °C | 65% |
SELF-DISCHARGE CHARACTERISTICS
| Storage time | Remaining capacity |
|---|---|
| 3 months | 91% |
| 6 months | 82% |
| 12 months | 64% |
Discharge Characteristics

Charging Characteristics

Capacity Retention (Self-Discharge)

Float Service Life

STANDARDS & QUALITY
AGM VRLA batteries produced by an ATB-approved manufacturing partner whose VRLA batteries are UL-recognized components under UL 1989, in facilities certified to ISO 9001, ISO 14001 and ISO 45001. Sealed, non-spillable VRLA construction.
Values are subject to variation of ±5% under normal manufacturing processes. Technical specifications are subject to change without prior notice. Curves represent typical performance for the AGM VRLA cell platform at the stated reference conditions. This product is engineered, specified and branded by ATB Power. E&OE. © ATB Power.