AGM  /  2V Series  /  Datasheet

ATB AGM 2V-100

2V Series · Long Life AGM VRLA
ATB-AGM-2V-100

2 V AGM cells.
Long-life standby power.

A 2 V 109 Ah 2 V AGM VRLA cell for telecom, networking, UPS and utility standby applications. Sealed, maintenance-free and non-spillable, with M8 bolt terminals.

ATB-AGM-2V-100
2 V
Nominal voltage
109 Ah
C20 capacity @ 25°C
840 A
Max discharge (5 s)
5.6 kg
Approx. weight

Sealed AGM VRLA

Valve-regulated oxygen-recombination design. Maintenance-free and non-spillable: no electrolyte topping and no acid handling.

M8 bolt terminals

Threaded M8 terminals for secure bolted cable connections in UPS, telecom and storage systems.

Single-cell format

2 V cells build 12, 24, 48 V and higher strings for standby systems.

Standard footprint

171 × 72 × 210 mm case.

SPECIFICATIONS

MECHANICAL

Length171 mm ±1.5
Width72 mm ±1.5
Container height204 mm ±2.5
Overall height210 mm ±2.5
Approx. weight5.6 kg ±3%
Container materialABS, UL94-HB (UL94-V0 optional)
Terminal typeM8 bolt terminal

ELECTRICAL

Nominal voltage2 V
ChemistryAGM VRLA (sealed)
Capacity, 20 hr (C20)109 Ah
Capacity, 10 hr (C10)101 Ah
Capacity, 5 hr (C5)88.5 Ah
Rating basisto 1.80 V/cell @ 25°C
Float voltage @ 25°C2.25 – 2.30 V
Equalizing voltage @ 25°C2.35 – 2.40 V
Max charge current31.5 A
Max discharge current840 A (5 s)
Internal resistance (charged)≈ 1.2 mΩ
Operating temp. (dis / chg)−15°C~50°C / −15°C~40°C
Storage temp.−15°C~40°C
CONTAINER DRAWING — DIMENSIONS IN MM
Container drawing
Technical Specification

ATB-AGM-2V-100 — technical data

CONSTANT CURRENT DISCHARGE @ 25°C · UNIT: A
F.V (V/cell) / Time30 min45 min1 h3 h5 h8 h10 h20 h
1.60 V10475.263.127.519.012.610.55.69
1.67 V10374.162.227.318.712.410.45.61
1.70 V10173.161.327.018.312.210.35.55
1.75 V99.271.760.126.518.012.010.25.50
1.80 V97.269.257.326.117.712.010.15.44
1.85 V89.365.255.224.016.911.49.455.24
CONSTANT POWER DISCHARGE @ 25°C · UNIT: W/CELL
F.V (V/cell) / Time30 min45 min1 h3 h5 h8 h10 h20 h
1.60 V19114011952.736.724.720.411.2
1.67 V19013911852.536.324.420.211.1
1.70 V18913811752.235.724.120.011.0
1.75 V18713611551.435.223.819.810.9
1.80 V18413211050.734.723.719.710.8
1.85 V17112610746.833.122.618.810.5
EFFECT OF TEMPERATURE ON CAPACITY (10 HR)
TemperatureCapacity (10 HR)
40 °C102%
25 °C100%
0 °C85%
−15 °C65%
SELF-DISCHARGE CHARACTERISTICS
Storage timeRemaining capacity
3 months91%
6 months82%
12 months64%
CHARACTERISTIC CURVES
Discharge Characteristics
TERMINAL VOLTAGE (V/CELL) vs DISCHARGE TIME · 25°C / 20°C
Discharge Characteristics
Charging Characteristics
0.1 CA · 2.25 V/CELL @ 25°C
Charging Characteristics
Capacity Retention (Self-Discharge)
CAPACITY RETENTION RATIO vs STORAGE TIME
Capacity Retention (Self-Discharge)
Float Service Life
FLOAT LIFE vs BATTERY TEMPERATURE · 2.25 V/CELL
Float Service Life

STANDARDS & QUALITY

AGM VRLA batteries produced by an ATB-approved manufacturing partner whose VRLA batteries are UL-recognized components under UL 1989, in facilities certified to ISO 9001, ISO 14001 and ISO 45001. Sealed, non-spillable VRLA construction.

Values are subject to variation of ±5% under normal manufacturing processes. Technical specifications are subject to change without prior notice. Curves represent typical performance for the AGM VRLA cell platform at the stated reference conditions. This product is engineered, specified and branded by ATB Power. E&OE. © ATB Power.